$5,950.00
4328 SENSIBLE BTUH @ 55F.
CellarPro’s AH4500SCv-ECX ducted cooling units (1/4 Ton Nominal) are engineered for wine cellars up to 1250* cubic feet in both commercial and residential wine cellars. When ducted, this unit uses 8-inch insulated ducting on the cold side, and 8-inch ducting on the hot side.
This Ducted Wine Room Cooling Unit maintains optimal cellar temperature and humidity conditions in extreme conditions up to 110F. Ducted Wine Room Cooling Unit use energy-efficient EC fans and are significantly quieter than comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands.. Visit our Learning Center for data tables, performance charts and product comparisons among different brands.
When the condensing unit will be exposed to or pulling air that is below 40F, our Compressor Heater (P/N 1727) is a required addition to protect the compressor. For installation of the condensing unit in environments below 20F down to -20F, our Fan Cycling Switch (P/N 6972) is required in addition to the Compressor Heater, and Electronic Configuration is required.
*Assuming R19 insulation throughout the cellar, 55F inside the cellar and 85F outside the cellar. Cold-side ducting, glass and/or uninsulated walls, extreme humidity, altitude and other factors may affect the sizing calculation.
Our cooling units are designed to be used in properly-constructed wine cellars that are adequately insulated, airtight and sealed with a vapor barrier. In improperly-constructed cellars, the cooling unit will create excess condensation, leading to damage and premature failure of your cooling unit (not covered by warranty).
CellarPro AH4500SCv-ECX Ducted Wine Room Cooling Units are fully-charged and ready to use out of the box. These cooling units are designed to be ducted up to 100 Equivalent Feet (50 Feet per Duct) with 8-inch ducting .
CellarPro’s vertical configuration allows multiple ducting alternatives, as follows.
Collars or grills for EXHAUST (ie Supply) are located at the front (shown at left), right, rear or top (EVAPORATOR ONLY) of the cooling system, and are interchangeable to meet your specific requirement.
Collars or grills for INTAKE (ie Return) are located on the left for both the evaporator and condenser, and include professional-grade air filters to protect the unit.
We recommend pulling the fresh air intake (hot-side) from a temperature-controlled environment other than the cellar. If the hot-side exhaust will be directed to a different space than the intake, always make sure that both spaces are sufficiently voluminous so that you don’t run into issues with negative pressure.
A bottle probe temperature sensor (10′ cord) plus your choice of duct collars, indoor grills and blank plates are included in the price of the cooling system.
CellarPro Air Handlers use two 110V / 60Hz plug-in power cords, as follows:
One cord for the compressor, which pulls 7.4 amps and requires a dedicated 15 amp circuit breaker
One cord for the rest of the components, which pull 3.2 amps and require a dedicated 15 amp circuit breaker
The data above is not valid when the integrated heater and/or humidifier are configured with the cooling unit
When the control panel is difficult to access, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar.
When not ducted, the hot side of the cooling unit (condenser) requires 12 inches of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space.
For installations in environments below 40F, AH4500SCv units require our Compressor Heater (P/N 1727) .
For installation in environments below 20F down to -20F , our Fan-Cycling Switch (P/N 6972) is required in addition to the compressor heater (both sold separately).
The cold side of the cooling unit (evaporator) should never be exposed to temperatures below 32F.
We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge.
4328 SENSIBLE BTUH @ 55F.
CellarPro’s AH4500SCv-ECX ducted cooling units (1/4 Ton Nominal) are engineered for wine cellars up to 1250* cubic feet in both commercial and residential wine cellars. When ducted, this unit uses 8-inch insulated ducting on the cold side, and 8-inch ducting on the hot side.
The BTU/h value shown here is a theoretical number. There are often circumstances under which a cellar design may require a larger unit due to variables not accounted for in the formula. For example, these variables could be building materials (such as glass, stone, concrete, etc.)
Which do not offer the insulation capacity required to maintain the optimal cellar environment. We recommend purchasing a unit with a larger capacity to compensate for these unaccounted-for variables. An undersized unit can lead to premature failure and will most likely prevent the cellar from reaching your desired temperature
Brand: CellarPro
Size: 18 3/5w x 18 3/5d x 37 9/10h (in), 8-inch ducting
Weight: 212 lbs
Power/Rating:
– CellarPro Air Handlers use two 110V / 60Hz plug-in power cords, as follows:
– Startup Amps: 42.0 Amps
– Running Amps Cord-Connected: 10.6 Amps
– Total Watts: 636 (medium fan speed)
– 1/2 Ton Nominal
BTUH @ 55F
– Low Fan Speed: 3607
– Med Fan Speed: 3975
– High Fan Speed: 4328
Decibels
Evaporator Decibels
– Low Fan Speed, Ducted: 38 dbA
– Med Fan Speed, Ducted: 44 dbA
– High Fan Speed, Ducted: 52 dbA
Condenser Decibels
– Low Fan Speed, Ducted / Non-Ducted: 43 dbA / 56 dbA
– Med Fan Speed, Ducted / Non-Ducted: 50 dbA / 63 dbA
– High Fan Speed, Ducted / Non-Ducted: 55 dbA / 68 dbA
Warranty Resources
– Warranty Overview

Cold Temperature
Filters & Grills
Remote Thermostats, Displays & Probes
Heating & Humidification
DID YOU KNOW?
Nobody protects your wine cellar better than CellarPro Cooling Systems! In the event your cooling unit fails and the failed components are covered by our warranty, we’ll send a replacement cooling unit to you per the terms of our Replacement Unit Program
CellarPro Replacement Unit Program
If your CellarPro cooling unit fails and the parts that failed are still covered by warranty, we’ll send a replacement cooling unit to you, as follows:
Please note: