CellarPro AH6500SCh Ducted Split System. CellarPro made the AH6500SCh Ducted Wine Room Cooling Systems. In order to provide maximum cooling power and adjustable humidity control for cellars up to 1,750 cubic feet. The evaporator and the condensing unit each can be ducted up to 100 equivalent feet (50 equivalent feet per duct.)
Made for internal installations, the Wine Room Cooling Systems includes a variable-speed fan on the evaporator. With a low setting for quieter operation and a high setting for maximum power. This Wine Room Cooling Systems has a horizontal configuration for installations in locations with limited height and/or vertical constraints (eg above the ceiling in an attic).
- CellarPro Wine Room Cooling Systems are made to be ducted on the cold side (evaporator), on the hot side (condensing unit), or both, allowing the equipment can be located out-of-sight where it won’t be heard.
- Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of cooling power to meet ambient and seasonal requirements.
- Optional integrated humidifier provides the ultimate control of moisture levels inside your cellar.
- Optional integrated heater (900W and 1800W) provides heat for wine cellars that are exposed to temperatures below 55°F.
- Extra-large coils generate maximum cooling power inside the cellar.
- Excess condensate is managed through an extra-large 1/2″ drain line, amply sized to reduce blockages.
- Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion.
- Intuitive LED display panel with digital programmable thermostat is simple and easy to use.
- Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
5771 SENSIBLE BTUH @ 55F.
CellarPro’s AH6500SCv ducted cooling units (3/4 Ton Nominal) are suitable for wine cellars up to 1,750 cubic feet in both commercial and residential wine cellars.
The BTU/h value shown here is a theoretical number. There are often circumstances under which a cellar design may require a larger unit due to variables not accounted for in the formula. For example, these variables could be building materials (such as glass, stone, concrete, etc.)
Which do not offer the insulation capacity required to maintain the optimal cellar environment. We recommend purchasing a unit with a larger capacity to compensate for these unaccounted-for variables. An undersized unit can lead to premature failure and will most likely prevent the cellar from reaching your desired temperature.
Brand: CellarPro
Size: 18 3/5w x 18 3/5d x 37 9/10h (in) 10-inch ducting
Weight: 212 lbs
Power/Rating:
Power:
– CellarPro Air Handlers use two 110V / 60Hz plug-in power cords, as follows:
- One cord for the compressor, which pulls 11.5 amps and requires a dedicated 20 amp circuit breaker
- One cord for the rest of the components, which pull 3.2 amps and require a dedicated 15 amp circuit breaker
– Startup Amps: 53.0 Amps
– Running Amps Cord-Connected: 14.7 Amps
– Total Watts: 944 (medium fan speed)
– 3/4 Ton Nominal
BTUH @ 55F
– Low Fan Speed: 4923
– Med Fan Speed: 5350
– High Fan Speed: 5771
Decibels
Evaporator Decibels
– Low Fan Speed, Ducted: 38 dbA
– Med Fan Speed, Ducted: 44 dbA
– High Fan Speed, Ducted: 52 db
– Common dedicated 25-amp circuit is required to power the unit.
Condenser Decibels
– Low Fan Speed, Ducted / Non-Ducted: 43 dbA / 56 dbA
– Med Fan Speed, Ducted / Non-Ducted: 50 dbA / 63 dbA
– High Fan Speed, Ducted / Non-Ducted: 55 dbA / 68 dbA
Cold Temperature
- Compressor Heater #1727: protects the unit when installed in environments that drop below 40F down to 20F
- Fan Cycling Switch #6972: supports the unit in temperatures below 20F and as low as -20F when configured with Electronic Control and combined with our compressor heater.
Filters & Grills
- Use our filter & grill guide to find the cooling unit filter or duct filter and/or duct grill that is appropriate for your cooling unit.
Remote Thermostats, Displays & Probes
- Networkable Thermostats #27346 and #27310: connect your cooling unit to a networkable, wi-fi enabled thermostat (sold separately). Must be ordered at the same time that the equipment is ordered. Other limitations apply – read the networkable thermostat description for more information. Includes 10 feet of wiring.
- Remote Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring. Additional wiring is available at a cost of $0.50 per additional foot.
- Bottle Probe #1434: this remote thermostat with a 10-foot cord overrides the thermostat on the face of the cooling unit, and allows it to monitor air or liquid temperatures at various locations inside the cellar – included.
- Bottle probe extension cords are available in 25-foot (#1780) and 50-foot (#1781) lengths.
Heating & Humidification
- Integrated Heater 900W #7237: adds 900 watts of heat through the cooling system when the cellar is in an unheated environment and will be exposed to temperatures below desired wine storage temperatures.
- Integrated Humidifier #7236: provides humidification with digital control inside the cellar when attached to an external water line.
DID YOU KNOW?
Nobody protects your wine cellar better than CellarPro Cooling Systems! In the event your cooling unit fails and the failed components are covered by our warranty, we’ll send a replacement cooling unit to you per the terms of our Replacement Unit Program
CellarPro Replacement Unit Program
If your CellarPro cooling unit fails and the parts that failed are still covered by warranty, we’ll send a replacement cooling unit to you, as follows:
- Your cooling unit must be registered at CellarPro
- Your cooling unit must have been properly sized, installed and maintained
- Your cooling unit may not have been permanently modified, damaged or disfigured
Please note:
- Replacement units are factory-refurbished cooling units with a similar build date as your original unit
- You are responsible for the shipping cost to send the replacement unit to you and return the original unit to us, and the cost (if any) to remove the original unit and install the replacement unit
- In order to send a replacement unit, we require a deposit, which will be refunded minus shipping costs upon the return and pending the inspection of the original unit
- If the original unit failed due to improper intallation or use, the failure is not covered by warranty and we will deduct the cost of the repairs from the refund of your deposit