The new 220V condenser can be placed outdoors, without the need for an exterior enclosure, the 110V condenser would need. The 220 H.E condenser is secured to the wall by a bracket with noise dampering grommets. (Does increases DB levels)
The new 220V condenser can be placed outdoors, without the need for an exterior enclosure, the 110V condenser would need. This condenser is secured to the roof.
The new 220V condenser can be placed outdoors, without the need for an exterior enclosure, the 110V condenser would need. This condenser is secured to the concrete pad.
Easy access to controls & valves for simplified installation + smart communication cable from evaporator to condenser.
Utilizes large, low-speed fans to create substantially lower operation sound levels between (45dB-52dB).
We’ve placed QR codes to directly lead you to all the vital information about installing and maintaining your system.
Liquid line 1/4” OD; Suction line 3/8” OD (less than 50 ft.), 1/2” (greater than 50 ft.)
220V (15-amp dedicated circuit required)
31.18″L x 10.75″W x 21.18″H
48
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.
Liquid line 1/4” OD; Suction line 1/2” OD (less than 50 ft.), 5/8” (greater than 50 ft.)
220V (15-amp dedicated circuit required)
31.18″L x 10.75″W x 21.18″H
45
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.
Liquid line 1/4” OD; Suction line 1/2” OD (less than 50 ft.), 5/8” (greater than 50 ft.)
220V (15-amp dedicated circuit required)
31.18″L x 10.75″W x 21.18″H
45
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.
Liquid Line 3/8″ OD; Suction Line 5/8″ OD (less than 50 ft.), 3/4″ (greater than 50 ft.)
220V (15-amp dedicated circuit required)
31.18″L x 10.75″W x 21.18″H
48
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.
Liquid Line 3/8″ OD; Suction Line 5/8″ OD (less than 50 ft.), 3/4″ (greater than 50 ft.)
220V (15-amp dedicated circuit required)
31.18″L x 10.75″W x 23.25″H
52
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.